State of the Art, Inc. resistor products are capable of withstanding short duration pulses that exceed the device's power or voltage ratings. Pulses less than the short time overload test conditions (2.5 times the operating voltage, not to exceed two times the voltage rating for 5 seconds) are easily accommodated by the devices. Pulses exceeding the short time overload test conditions must be assessed on a case-by-case basis. Please consult our factory for an assessment of your application.